Every Manual J, S, and D calculation follows ACCA standards and meets city, county, and state building requirements nationwide.
No matter where your project is located - we deliver fast, precise calculations tailored to your local climate zone.
Most projects delivered within 3–5 days, with rush options available.
You’ll work directly with Sean, the load-calculation specialist handling your project from start to finish.
Upload your plans and basic information using our intake form. We will then get back to you with any additional information we may need. After that we will provide you with a Quote based on your project's specific information.
We then perform the calculations in the order of Manual J (Loads), Manual S (Equipment), and Manual D (Duct Design) using IECC / ACCA standards.
Once finished you will receive a full permit ready PDF package of your home.
✅ Architectural Plans (DWG or PDF)
✅ Project Adress
✅ Wall / Roof / Floor U-values or Details
✅ Window U-values & SHGC
✅ ACH / Infiltration Rate (Why we recommend a Blower Door Test)
✅ Indoor Design Temperatures
✅ Preferred Equipment (Manufacturer, Equipment Type, etc.)
✅ Any AHJ Notes
✅ Ventilation Information (ERV or HRV)
We use advanced ACCA-approved software to calculate the exact heating and cooling loads for your project. Every room is analyzed for insulation, windows, infiltration, and orientation to ensure your home performs at peak efficiency.
Full room-by-room heating & cooling load report
Design Conditions
Building envelope summary
Infiltration & Ventilation loads
Internal Gains
Climate Zone & Orientation effects
Using the Manual J results, we select properly matched HVAC equipment that meets system requirements without oversizing. This ensures comfort, lower energy bills, and extended equipment life.
Equipment selection table
Sensible / Latent Capacity Verification
Check for Oversizing Limits
Cooling and Heating Performance Data
Matching Indoor / Outdoor Unit Data
SEER/HSPF efficiency validation for compliance
Any notes for Plan Reviewers
We provide detailed duct layouts and sizing based on pressure drop, friction rate, and airflow balance. Each design is optimized for quiet operation, comfort, and efficiency. Duct design/layout based on your specific needs.
Duct layout schematic (PDF)
Supply and return airflow balance report
Friction loss Results
Velocity Checks
Supply and Return Sizing
Static Pressure & Total ESP
Ductwork Material Type
Service
Manual J
Manual J & S
Manual JSD
Details
Full room-by-room load calculation
Full Manual J & Proper HVAC equipment sizing
Complete ACCA-compliant set
Typical Price
$219-$1000+
$279-$1500+
$449-$2000+
Pricing varies by square footage, complexity, and equipment types. Multi-unit and Builder discounts available.
I’m not a contractor or a software button-pusher—I’m a Mechanical Engineer with 5+ years of professional energy modeling and HVAC design experience.
My background is in full-building energy simulation, where precision matters. I work with the same tools used on commercial and high-performance buildings to evaluate heat loss, heat gain, ventilation, and system performance before equipment is ever selected.
That experience translates directly into more accurate Manual J, S, and D calculations than what most residential providers can offer.
If you want calculations done the way an engineer would do them—carefully, conservatively, and correctly—you’re in the right place.
Manual JSD calculations aren't just paperwork, they're the foundation of an efficient system that actually performs at the lowest possible cost to the homeowner. A properly sized, well balanced HVAC design ensures:
Every room reaches the correct temperature year-round.
Equipment runs efficiently and lasts longer.
Ductwork is quiet, balanced, and easy to install.
Inspectors approve your plans the first time.
Installation of equipment runs smoothly.
We deliver ACCA-compliant Manual J, S & D reports anywhere in the U.S. and tailor each submittal to your local code and permit requirements. Where jurisdictions follow IECC/IRC (2015 or newer) we size equipment per Manual S using Manual J loads and provide Manual D duct design as required. If your state or city needs specific forms or documentation, we’ll work with you to ensure you receive the correct package for your specific location. No matter where your project is located, we deliver code-compliant, ACCA based reports ready for permitting.
Now Serving:
Alabama | Alaska | Arizona | Arkansas | California | Colorado | Connecticut | Delaware | Florida | Georgia | Hawaii | Idaho | Illinois | Indiana | Iowa | Kansas | Kentucky | Louisiana | Maine | Maryland | Massachusetts | Michigan | Minnesota | Mississippi | Missouri | Montana | Nebraska | Nevada | New Hampshire | New Jersey | New Mexico | New York | North Carolina | North Dakota | Ohio | Oklahoma | Oregon | Pennsylvania | Rhode Island | South Carolina | South Dakota | Tennessee | Texas | Utah | Vermont | Virginia | Washington | West Virginia | Wisconsin | Wyoming